Sonic Compressional ∆t Display
The digital acoustic logging tool is based on the theory of 2 transmitters and 4 receivers structureand GTS transmission mode.By measuring the slowness of longitudinal waves in the stratum to determine the total porosity of strata.Meanwhile, it can provide 3in CBL and 5in VDL for casing bond quality.All the electronic circuits are installed in the mandrel, thus instrument is lighter and length is shorter.
Specification:
Max. Temperature:175℃,4h
Max. Pressure:140Mp
Min. Hole Diameter:114mm/4.49 inches
OD: 89mm/3.5inches
Make-up Length:3897mm/153.43 inches
Shipping Length:4365mm/171.85 inches
Max. Logging Speed:18.0m/min
Measuring Accuracy: ±0.5μS/ft
Repeatability: ±1%
Vertical Resolution:152.4mm/6inches
Operating Voltage & Current:180VAC,6-10mA
Wireline Requirement:Seven Conductor Cable ,30kft maximum length for most cable sizes and types
Max. Tensile Strength:17000lb Max. Compressive Strength:4000lb
Sensor Type
Receivers:
Type:Piezoelectric(monopole)Bandwidth:wideband(1-25kHz)
Number:4
Spacing:152mm
Offset:min0.914m
Max 1.98m Transmitters:
Number: 2 Spacing: 600mm