SK-WFS Well Factory Logging Unit

Overview
SK-WFS Well Factory Logging Instrument is a new generation of oil exploration and development equipment developed to meet the needs of shale gas drilling site logging. It is based on the company's accumulated professional technology over the years, relying on the company's advantages in scientific and technological talents and Shanghai's strong industrial foundation. The instrument is in the leading position in China in terms of overall design and manufacturing technology, and has reached the international advanced level.

SK-WFS well factory logging instrument adopts a set of logging instruments to realize simultaneous logging of two or more wells on site. It is not only equipped with conventional fast chromatograph and CAN bus data acquisition system, but also equipped with wireless sensors and wellhead chromatography system, which can fully meet the logging tasks in the well factory operation mode.


Highlights
1. The logging instrument room provides a work area for logging personnel, making the working environment more comfortable.
2. The chromatograph is installed at the wellhead to shorten pipeline delay and obtain gas test results faster.
3. The wireless sensor system reduces on-site wiring and meets the requirements for rapid installation of multiple wells.
4. Reduce on-site logging personnel and reduce logging costs.
5. Dual servers at the well site and base meet remote logging requirements.



Technical Indicators

Power Equipment
***Isolation transformer
Input Voltage:380V(Optional: 480V、440V、220V)
Input frequency: 50Hz
Output Voltage: 380V±5% Output frequency: 50Hz

***UPS Uninterruptible Power Supply
Input Voltage: 220V±10%
Input Frequency: 35~65Hz
Output Voltage: 220V±2%
Output Frequency: 50±1Hz
Battery life: ≥15 min


***Instrument room safety indicators
The insulation resistance between the phase line and the grounding wire in the machine room is greater than 2MΩ, and the instrument must be equipped with a good grounding device.

Gas Analyzers
***SK-3Q06 Flash Chromatograph
1. Analysis cycle:30, 90s (custom analysis cycle time)
2. Detection components:C1~nC5
3. Minimum detection concentration:Total hydrocarbons 1×10-6, hydrocarbon components 1×10-6
4. Measuring range:Total hydrocarbons 1×10-6~1, hydrocarbon components 1×10-6~1
5. Methyl and ethyl ethane separation:≥0.85, obvious separation under 1% methane mixed gas (C1/C2 300:1) conditions
6. Noise:≤0.5% F.S/h
7. Stable baseline:≤1% F.S/h
8. Repeatability error:≤2.5% F.S

***ChromWizard Wellhead Chromatograph
1. Working Area:Positive pressure explosion-proof zone 1 and zone 2
2. Length x width x height (cm):(H)90×(W)80×(D)30
3. Weight:50kg (the explosion-proof control box and the positive pressure box are independent and can be quickly connected and installed on site)
4. Chromatography Principle: Catalytic combustion
5. Analysis cycle: 60s(C1-C5)
6. Minimum detection concentration of components: 10ppm(C1) 7. Minimum detection concentration of total hydrocarbons: 10ppm(C1)
8. Carrier gas: Air
9. Degassing method: Conventional degasser
Wireless data transmission, and support WITS data transmission
10. Ambient temperature : -20 - +60 ℃



Sensors
Sensors (CAN Wireline, 7W01 wireless)
Pump stroke sensor/turntable speed sensor: Range: 0-1920 strokes/min
Turntable Torque Sensor: Range: 0~6MPa
Standpipe pressure sensor: Range: 0~42MPa
Casing Pressure Sensor: Range: 0~68MPa
Hook weight sensor: Range: 0~6MPa
Drilling fluid temperature sensor: Range: 0~125℃
Drilling Fluid Density Sensor: Range: 0~3g/cm3
Drilling Fluid Conductivity Sensor: Range: 0~50ms/cm, 0~300ms/cm
Drilling fluid outlet flow sensor: Range: 0~100% (relative flow)
Drilling fluid pool volume sensor: Range: 0~5m
Winch Sensor: Measuring range: 0~9999, hook position setting: 0~50m
Hydrogen Sulfide Sensor: Range: 0~100ppm, response time: T80<30s


SK-7W01 Wireless Sensor

***SK-7W01Wireless sensor
Network Node: 64
Transmission distance: 100m
Operating temperature: -30-60 ℃
Explosion-proof certification: Wireless node: Ex ia IIC T4 / Wireless host: Ex nA IIC T4

Battery powered continuous working time exceeds 3 months

Geological Instruments

***Carbonate Analyzer
Measuring range: 0~100% Carbonate
Accuracy: 1%

***Mudstone Density Tester
Measuring range: 1~3g/cm3
Minimum sample weight: 0.05g
Resolution: 0.01g/cm3

***Fluorometer
Power supply: 220VAC、50Hz
power: 40W

***Thermal Vacuum Distillation Degasser
Power supply: 220VAC、50Hz
heating power: 300W
System vacuum: ≤1.3KPa
System sealing: After the vacuum reaches 1.3KPa, the vacuum gauge should not drop more than 0.26KPa within 2 hours after the air valve is shut off.
Mud bottle capacity: 250ml

Электрический деаэратор
***Электрический дегазатор
Operating Voltage: Three-phase 380VAC
power: 370W
Rotating speed: 1400rpm
Explosion-proof grade: ExdIIBT4

Software System

Windows operating system
Available in Chinese, English, Russian and Spanish
Metric, Imperial and custom unit conversion
Rich background application software
Any Questions or Comments? Please Leave a Message. Our Experts Shall Contact You Soon.
  • Name*

    *
  • Email*

    *
  • Phone*

    *
  • Message