SK-CMS Comprehensive Mud Logging Unit

SK-CMS comprehensive mud logging instrument has been widely recognized by mud loggers. It not only serves major domestic oil fields, but also goes abroad to serve more than ten countries and regions such as the United States, Russia, India, Pakistan, etc., becoming a real national brand.

Instrument Features

Differential chromatography: solves the problem of identifying true and false oil and gas displays caused by oil mixing, addition of organic additives and drilling fluid pollution.
Explosion-proof CAN bus transmission: simplifies sensor installation, easy expansion, automatic fault diagnosis, and self-protection.
Remote transmission: realizes real-time information transmission between the well site and the remote base regardless of the communication method.
Dual-machine hot backup: adds double insurance to ensure the normal operation of logging work and data security.
Well site information center: open database structure and WITS standard interface to achieve integration with third-party data.
Paperless records: realize paperless records and logging process reproduction that cannot be modified in the whole process, and can directly generate PDF documents.
Professional abnormal warning: engineering abnormality prediction expert system can reduce the occurrence of engineering accidents, greatly reduce operational risks, and ensure the safety of drilling construction.
Comprehensive evaluation of oil and gas: integrates various information such as engineering, gas measurement, geological analysis, etc., greatly improving the interpretation and evaluation compliance rate of oil, gas and water layers.
Rich application software has withstood international tests - Chinese, English and Russian versions meet international service needs.

Technical Indicators
Power supply
Flameproof transformer

Input Voltage   : 380V(Optional: 480V、440V、220V)
Input Frequency: 50Hz
Output Voltage: 380V±5%
Output Frequency: 50Hz

UPS Uninterruptible Power Supply
Input Voltage: 220V±10%
Input Frequency: 35~65Hz
The output voltage: 220V±2%
Output frequency: 50±1Hz
Battery life: ≥15min

Instrument room safety indicators
The insulation resistance between the phase line and the grounding wire in the equipment room is greater than 2MΩ, and the instrument must be equipped with a good grounding device.

Gas analyzers
Natural Gas Hydrocarbon Component Analyzer
Analysis cycle: 30, 90s (custom analysis cycle time)
Detection components: C1~nC5
Minimum detection concentration: Total hydrocarbons 1×10-6, hydrocarbon components 1×10-6
Measuring range: Total hydrocarbons 1×10-6~1, hydrocarbon components 1×10-6~1
Methyl and ethyl ethane separation: ≥0.85, obvious separation under 1% methane mixed gas (C1/C2 300:1) conditions
noise: ≤0.5% F.S/h
Stable baseline: ≤1% F.S/h
Repeatability error: ≤2.5% F.S

Natural Gas Non-Hydrocarbon Component Analyzer
Measurement content: CO2
Minimum detection concentration: CO2 0.1%
Measuring range: CO2 0.1%~100%
Baseline drift: Full scale 1%/7d
Repeatability error:±5%
Sensors
Pump stroke sensor/turntable speed sensor:Range: 0-1920 strokes/min
Turntable Torque Sensor:Range: 0~6MPa
Standpipe pressure sensor:Range 0~42MPa
Casing Pressure Sensor:   Range 0~68MPa
Hook weight sensor:Range 0~6MPa
Drilling fluid temperature sensor: Range 0~125℃
Drilling Fluid Density Sensor:Range0~3g/cm3
Drilling Fluid Conductivity Sensor:Range 0~50ms/cm, 0~300ms/cm
Drilling fluid outlet flow sensor:Range 0~100% (relative flow)Drilling fluid pool volume sensor:Range 0~5m
Winch Sensor:Measuring range: 0~9999, hook position setting: 0~50m
Hydrogen Sulfide Sensor:Range: 0~100ppm, response time: T80<30s
Geological Instruments
Carbonate Analyzer
Measuring range:0~100% Carbonate
Accuracy:1%

Mudstone Density Tester
Measuring range1~3g/cm3
Minimum sample weight0.05g
Resolution0.01g/cm3

FluorometerPower supply:220VAC、50Hz
Power:40W
Thermal Vacuum Distillation Degasser
Power supply:Power supply
heating power:300W
System vacuum:≤1.3KPa
System sealing:After the vacuum reaches 1.3KPa, the vacuum gauge should not drop more than 0.26KPa within 2 hours after the air valve is shut off.
Mud bottle capacity:250ml

Electric degasser
Operating Voltage:Three-phase 380VAC
Power:370W
Rotating speed:1400rpm
Explosion-proof grade:ExdIIBT4
Software System

Windows operating system
Available in Chinese, English, Russian and Spanish
Metric, Imperial and custom unit conversionRich background application software