SK-AGR Azimuth Gamma Ray Probe While Drilling

SK-AGR is a probe-type azimuth gamma measurement while drilling tool compatible with the Tensor standard, with a maximum operating temperature of 175°C and a pressure resistance of 25000Psi.

The azimuth gamma probe while drilling is suitable for high-angle directional wells and horizontal wells. In the construction of complex formations and thin reservoirs, it can accurately indicate the approach to the boundary or the boundary, and can provide direction, providing a basis for geological engineers to plan wellbore trajectories and real-time geological guidance, effectively improving the drilling rate.

Product Features Dual-channel gamma real-time measurement Can provide up, down, left, right and total gamma during inclination increase, inclination decrease and compound drilling Accurate environmental correction algorithm Advanced azimuth algorithm, good azimuth signal recognition Internal real-time clock, measure and record drilling tool speed, vibration, stick-slip and other working conditions Compatible with Tensor and Centerfire systems Can be customized to connect to third-party MWD and LWD tools
240 RPM Maximum operating speed
175℃ Maximum operating temperature
25000 Psi Maximum working pressure
Product Specifications
Sensitivity1 CPS/API
Measurement accuracy

±5%@150℃

± 10%@175℃

Measuring sectors16 sectors
Measuring range0 ~1000 API
Maximum operating speed240 RPM
Operating voltage18 ~36 V
vibration25g /rms
Shock1000g /0.5ms
Mechanical Dimensionsφ47.6mm *2050mm

Temperature gradetypeCycle temperature (℃)Limit temperature (℃)Sensitivity (cps/Api)Contrast
Medium temperatureDual Focus15016511 : 3.5
high temperature175185