Product Features
Preset flash point/burning point/flash point/search flash point four modes for users to choose
7” color touch screen, supports Chinese, English and Russian
High-speed signal processor control, high-precision analog/digital conversion circuit, high test accuracy
Fuzzy adaptive PID control algorithm, automatically adjusts the heating curve according to standard requirements
Removable ion ring, convenient for cleaning and maintenance
Plug-in electronic igniter set, more convenient to replace
With atmospheric pressure calibration and temperature compensation function
Imported wire-wound PT100 platinum resistance temperature probe, accurate temperature measurement
Heating limit safety protection, the instrument automatically stops and alarms when the limit temperature is reached, and automatically cools at the same time
Fault self-diagnosis system and reminder function
Can automatically store no less than 5000 test results
The instrument adopts iSKvator technology to automatically complete the entire process of ignition, sweeping, lifting, testing, fire extinguishing and cooling test
RJ-45 standard interface, can be connected to LIMS
Technical Specifications | |
Test Method | Meet GB/T 3536, ASTM D92, ISO 2592, IP 36 |
Flash point/fire point measurement range | 79~370℃(175~698℉) |
Display accuracy | 0.1℃ |
Repeatability | ≤6℃ |
Reproducibility | ≤8℃ |
Security | Temperature limit safety protection, when reaching the limit temperature, the instrument automatically stops and alarms, and automatically cools down. Safety protection limit temperature: Flash point mode: EFP (expected flash point temperature) +20℃ Flash point mode: EFP (expected flash point temperature) +50℃ Absolute safety protection: 400℃ |
Gas source | Liquefied gas, butane gas, pipeline gas, natural gas (pressure <10kPa) |
Cooling method | Air cooling system |
Ignition system | Automatic gas ignition, electric heating wire ignition |
Flash point detection | Ion flame detection |
Sample temperature detection | Imported wire-wound PT100 platinum resistance temperature probe |
show | 7-inch color touch screen, supports Chinese, English, Russian |
calibration | Atmospheric pressure calibration and temperature compensation |
data | Can automatically store no less than 5000 test results |
Communication interface | RS232,RJ-45 |
Data Output | LIMS or Printer |
Machine power | 900W |
Heating furnace power | 800W |
Instrument use environment | Temperature: 5℃~35℃ No air flow Humidity: 20~90%RH at 35℃, no condensation |
Instrument power supply | AC 220V±10% 50/60Hz |
Dimensions | 530mm wide × 233mm deep × 427mm high |
Net weight of instrument | 19KG |